Hydralazine-selective PVC membrane electrode based on hydralazinium tetraphenylborate |
| |
Authors: | Badawy S S Shoukry A F Rizk M S Omar M M |
| |
Institution: | Department of Chemistry, Faculty of Science, Cairo University, Giza, Egypt. |
| |
Abstract: | A hydralazine ion-selective PVC membrane electrode based on hydralazinium tetraphenylborate has been prepared with dioctyl phthalate as plasticizer. The electrode showed linear response with a slope factor of 57.5 mV/concentration decade at 20 degrees over the concentration range from 4 x 10(-4) to 10(-1)M hydralazine. The effects, on the electrode performance, of membrane composition, pH of the test solution and the time of soaking were studied. The electrode exhibited good selectivity for hydralazine with respect to a large number of inorganic cations and organic substances of biological importance. The standard-addition method and potentiometric titrations were used to determine hydralazine concentrations in pure solutions and in a pharmaceutical preparation, with satisfactory results. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|