首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Separation of trace amounts of indium, gallium and aluminium from each other by cation-exchange chromatography on AG50-X4 resin
Authors:Strelow F W  van der Walt T N
Institution:National Chemical Research Laboratory, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, Republic of South Africa.
Abstract:Traces and minor amounts of indium, gallium and aluminium can be separated from gram amounts of thallium and from each other by cation-exchange chromatography on a column containing as little as 2 g of AG50W-X4, a cation-exchange resin with low cross-linking. An elution sequence of 0.1 M HBr in 40% acetone for Tl(III)], 0.2M HBr in 80% acetone for In, 0.3M HCl in 90% acetone for Ga and 3M aqueous HCl for Al is used. The separations are very sharp and even 10-mug amounts of In, Ga and Al in synthetic mixtures are recovered quantitatively, with a standard deviation of 0.3 mug. The separation factors between neighbouring ions are extremely large (> 5000).
Keywords:
本文献已被 PubMed 等数据库收录!