首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Ion chromatographic determination of lithium at trace level concentrations: Application to a tracer experiment in a high-mountain lake
Authors:Ulrike Nickus  Hansjrg Thies
Institution:

a Institute of Meteorology and Geophysics, University of Innsbruck, Innrain 52, A-6020 Innsbruck, Austria

b Institute of Zoology and Limnology, University of Innsbruck, Technikerstrasse 25, A-6020 Innsbruck, Austria

Abstract:The water residence time of a high-mountain seepage lake in the Austrian Alps was derived from the flushing rate of a tracer substance. A diluted lithium chloride solution was injected into the lake during holomictic conditions in order to favour the homogeneous distribution of the tracer. The exponential decline of the mass of lithium in the lake revealed a water residence time of 1.5 to 3 months for summer and almost no lake water exchange during winter. Lithium concentrations ranged from background values of 0.06 μg l?1 to about 3 μg l?1 immediately after the tracer injection. Lake water samples were analyzed with ion-exchange chromatography using a Dionex device with a CS 12A separation column. The method detection limit determined according to the definition of the US Envirinmental Protection Agency amounted to 0.009 μg l?1.
Keywords:Lithium chloride  Metal cations