Direct determination of bulk etching rate for LR-115-II solid state nuclear track detectors
Authors:T A Salama  U Seddik  T M Hegazy  A Ahmed Morsy
Institution:(1) Nuclear Physics Department, Nuclear Research Center, P.O. 13759, Cairo, Egypt;(2) Faculty of Girls, Ain-Shams University, P.O. Box, 11757 Cairo, Egypt
Abstract:The thickness of the removed layer of the LR-115-II solid state nuclear track detector during etching is measured directly with a rather precise instrument. Dependence of bulk etching rate on temperature of the etching solution is investigated. It has been found that the bulk etching rate is 3.2 μm/h at 60°C in 2.5 N NaOH of water solution. It is also found that the track density in detectors exposed to soil samples increases linearly with the removed layer.
Keywords:Bulk etching rate  LR-115-II  sensitivity