Abstract:The imine of polybenzimidazole (PBI) is chemically oxidized by hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopies (XPS) showed that when the AcOH concentration remained constant, the degree of oxidation increased with increasing H2O2 levels. Moreover, the imine also exhibited electrochemical redox behavior. Based on these properties, a PBI-modified Au (PBI/Au) electrode was developed as an enzyme-free H2O2 sensor. At an applied potential of −0.5 V vs. Ag/AgCl, the current response of the PBI/Au electrode was linear with H2O2 concentration over a range from 0.075 to 1.5 mM, with a sensitivity of 55.0 μA mM−1 cm−2. The probe had excellent stability, with <5% variation from its initial response current after storage at 50 °C for 10 days. Potentially interfering species such as ascorbic or uric acid had no effect on sensitivity. Sensitivity improved dramatically when multiwalled carbon nanotubes (MWCNT) were incorporated in the probe. Under optimal conditions, the detection of H2O2 using a MWCNT-PBI/Au electrode was linear from 1.56 μM to 2.5 mM, with a sensitivity of 928.6 μA mM−1 cm−2. Analysis of H2O2 concentrations in urine samples using a MWCNT-PBI/Au electrode produced accurate real-time results comparable to those of traditional HPLC methods.
Keywords:AA  ascorbic acid  AcOH  acetic acid  AcOOH  peracetic acid  DMSO  dimethyl sulfoxide  FE-SEM  field-emission scanning electron microscopy  FT-IR  Fourier transform infrared spectroscopy  MWCNT  multiwalled carbon nanotubes  PBI  polybenzimidazole imine  PBINO  PBI N-oxide  PBI/Au  PBI-modified Au  PBS  phosphate buffer solution  UA  uric acid  XPS  X-ray photoelectron spectroscopy