首页 | 本学科首页   官方微博 | 高级检索  
     检索      


HPLC method transfer study for simultaneous determination of seven angiotensin II receptor blockers
Authors:Khaled A Marghany  Randa A Abdelsalam  Ghada M Haddad
Abstract:In this study, a sensitive high‐performance liquid chromatography method was developed and validated for the simultaneous determination of seven angiotensin II receptor blockers, namely, hydrochlorothiazide, chlorthalidone, eprosartan mesylate, valsartan, losartan potassium, irbesartan, and candesartan cilexetil. Different chromatographic parameters were tested and fully optimized. Best chromatographic separation was accomplished on a reversed‐phase octadecylsilyl column (250 × 4.6 mm id; 5 μm) under gradient elution using methanol/sodium phosphate monobasic buffer (0.01 M, pH 6.5) as mobile phase. The detection of target analytes was obtained at 254 nm. The pH of the buffer has been selected according to Marvin® sketch software. The proposed method was validated according to ICH guidelines and showed good precision (relative standard deviation < 1), good linearity (square of correlation coefficient ≥ 0.999), and high accuracy (between 98 and 102%) with detection limit and quantitation limit (40 and 160 ng/mL, respectively) for all the detected analytes.
Keywords:antihypertensive medications  Marvin software  method transfer