首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of indoor radon levels in Erbil capital by using solid state nuclear track detectors
Authors:H.H. Mansour   S. per Khdar   H.Y. Abdulla   N.Q. Muhamad   M.M. Othman  S. Qader
Affiliation:

Physics Department, Science Education College, Salahaddin University-Erbil, Iraqi-Kurdistan Region

Abstract:Radon alpha activity concentration has been measured in 28 homes in the Erbil Capital-Iraqi Kurdistan region during the autumn season by using time-integrated passive radon dosimeters containing CR-39 solid state nuclear track detectors “SSNTDs”. The radon activity concentrations in these homes range from (10.33–90.34) with an average of . The average absorption effective dose equivalent for a person living in homes for which the investigation were done was found to be , obtained by using an equilibrium factor of 0.5 and an occupancy factor of 0.8. The average lung cancer cases per year per 106 person was found to be 23±12.
Keywords:Indoor Radon   SSNTDs dosimeter   Work level month   Potential alpha energy exposure   Lung cancer
本文献已被 ScienceDirect 等数据库收录!