Resolution of a racemic pharmaceutical intermediate. A comparison of preparative HPLC, steady state recycling, and simulated moving bed |
| |
Authors: | Grill Charles M Miller Larry Yan Tony Q |
| |
Institution: | Pharmacia, 4901 Searle Parkway, Skokie, IL 60077, USA. charles.m.grill@pharmacia.com |
| |
Abstract: | Preparative HPLC and simulated moving bed (SMB) chromatography were used to resolve significant quantities of a racemic pharmaceutical intermediate. In addition, smaller scale studies using closed-loop recycling and steady state recycling (SSR) were performed so that a meaningful comparison of all these techniques could be made using the same real world separation. A highly optimized, six-column SMB process was clearly the superior technique and was used for the process-scale (247 kg of racemate) resolution. At the more moderate lab-scale (33 kg of racemate and 19 kg of racemate), a frequently used but less optimized eight-column SMB process was used. It was found that SSR was comparable to the lab-scale SMB process in productivity and solvent consumption. Thus, it appears that SSR can be a useful choice at such moderate scales. Finally, at moderate scales when neither SSR nor SMB is available, it was found that acceptable results were obtained with both closed-loop recycling and with a two-step preparative process. |
| |