间歇电喷雾的初步研究
引用本文:刘晗青,郭寅龙,余翀天,杨芃原. 间歇电喷雾的初步研究[J]. 化学学报, 2002, 60(1): 171-175
作者姓名:刘晗青  郭寅龙  余翀天  杨芃原
作者单位:1. 中国科学院上海有机化学研究所,上海,200032
2. 复旦大学化学系,上海,200433
摘    要:设计了一种高灵敏的质谱离子化方法-间歇电喷雾,并介绍了间歇电喷雾的基本原理、稳定性和应用在蛋白质分析上的优势。这种质谱离子化方法能够显著地改善信噪比,降低对样品溶解度的要求,提高样品的离子化效率,减少样品的消耗和仪器的污染,可以预言间歇电喷雾的方法在蛋白质的分析上将会有广泛的应用前景。

关 键 词:间歇电喷雾  离子化  灵敏度  蛋白质  质谱
修稿时间:2001-04-29

Primary study for intermittent electrospray
LIU,Han-Qing GUO,Yin-Long YU,Chong-Tian. Primary study for intermittent electrospray[J]. Acta Chimica Sinica, 2002, 60(1): 171-175
Authors:LIU  Han-Qing GUO  Yin-Long YU  Chong-Tian
Affiliation:LIU,Han-Qing GUO,Yin-Long YU,Chong-Tian Shanghai Institute of Organic Chemistry,The Chinese Academy of Sciences,Shanghai 200032YANG,Peng-Yuan Department of Chemistry,Fudan University,Shanghai 200433
Abstract:We designed a new method-intermittent electrospray for mass spectrometry. In this paper, the primary principle for intermittent electrospray, the high sensitivity property of intermittent electrospray and advantages for protein analysis is described. Because of its high-sensitivity, this method may find extensive applications in analysis of proteins. The instrumental parameters can be controlled during intermittent electrospray if thesoftware of the instrument is reprogrammed. The parameters can be optimized to give better data. The parameters that can be controlled include tip potential, nozzle potential, flow rate, nebulizer gas flow, curtain gas flow and so on. The instrumental parameters can be changed during different electrospray process in this program. Each process has its own parameters. Then this program runs in cycle to electrospray intermittently. Intermittent electrospray has many advantages for mass spectrometry, which continuous electrospray doesn't have. For example, biological samples are always so little in quantity and the concentration of these samples is so low that many problems are encountered in the determination. But now this kind of samples can be analyzed by intermittent electrospray. Sample solutions are condensed at tip during nonionization time when the solvent is evaporated. After that the condensed sample solution is sprayed in a short time. Because the concentration of the solution is increased, the sensitivity is also improved. So satisfied results from the biological sample can be obtained. Some factors (such as tip potential, sample solution flow) that may influence sensitivity were studied.
Keywords:intermittent electrospray   mass spectrometry   high-sensitivity