X‐ray microtomographic visualization of Escherichia coli by metalloprotein overexpression |
| |
Authors: | Ryuta Mizutani Keisuke Taguchi Masato Ohtsuka Minoru Kimura Akihisa Takeuchi Kentaro Uesugi Yoshio Suzuki |
| |
Abstract: | This paper reports X‐ray microtomographic visualization of the microorganism Escherichia coli overexpressing a metalloprotein ferritin. The three‐dimensional distribution of linear absorption coefficients determined using a synchrotron radiation microtomograph with a simple projection geometry revealed that the X‐ray absorption was homogeneously distributed, suggesting that every E. coli cell was labeled with the ferritin. The ferritin‐expressing E. coli exhibited linear absorption coefficients comparable with those of phosphotungstic acid stained cells. The submicrometer structure of the ferritin‐expressing E. coli cells was visualized by Zernike phase contrast using an imaging microtomograph equipped with a Fresnel zone plate. The obtained images revealed curved columnar or bunching oval structures corresponding to the E. coli cells. These results indicate that the metalloprotein overexpression facilitates X‐ray visualization of three‐dimensional cellular structures of biological objects. |
| |
Keywords: | bacteria ferritin high‐Z element micro‐CT three‐dimensional structure |
|