首页 | 本学科首页   官方微博 | 高级检索  
     检索      

程序升温汽化大体积进样气相色谱法同时测定空气中的甲醛及其他10种羰基污染物(英文)
作者姓名:Stefano DUGHERI  Nicola MUCCI  Ilenia POMPILIO  Giovanni CAPPELLI  Costanza BOSSI  Alessandro BONARI  Giulio ARCANGELI
作者单位:Department of Experimental and Clinical Medicine, University of Florence, I-50141 Florence, Italy
摘    要:Long-term indoor-air limit for formaldehyde stipulated by the European Commission is 1 μg/m3,while the World Health Organization has set a threshold of 100 μg/m3 that should not be exceeded for more than 30 min. To date,however,only a few analytical techniques have been developed that can be used to detect formaldehyde at these very restrictive limits. Thus,there is a need to develop for comprehensive methods for analyzing airborne formaldehyde and other carbonyl pollutants in the ambient environment. The aim of this study is to develop a highly sensitive online automated preconcentration gas chromatographic method using large-volume injection with a programmed temperature vaporization injector for the analysis of airborne formaldehyde and ten other carbonyl compounds. The influence of several parameters,such as the maximum volume injected,programmed temperature vaporization transfer time and temperature,carrier gas flow rate,and type of packing material was investigated. After optimization,highly satisfactory results in terms of the absolute and methodological detection limits were achieved,i. e. as low as the μg/m3 level for all the carbonyl pollutants studied. A commercially available sampler,originally designed for active sampling,was evaluated as a passive sampling device;this optimized technique was applied to monitor the concentrations of carbonyl pollutants in the indoor air of ten public buildings in Florence. The strength of this methodology lies both in the low detection limits reached in the simultaneous analysis of a wide group of 2,4-dinitrophenylhydrazine derivatives,and the potential adaptability of this method to other gas chromatographic applications to achieve lower sensitivity.

收稿时间:2018-08-29

Determination of airborne formaldehyde and ten other carbonyl pollutants using programmed temperature vaporization-large volume injection-gas chromatography
Stefano DUGHERI,Nicola MUCCI,Ilenia POMPILIO,Giovanni CAPPELLI,Costanza BOSSI,Alessandro BONARI,Giulio ARCANGELI.Determination of airborne formaldehyde and ten other carbonyl pollutants using programmed temperature vaporization-large volume injection-gas chromatography[J].Chinese Journal of Chromatography,2018,36(12):1311-1322.
Authors:Stefano DUGHERI  Nicola MUCCI  Ilenia POMPILIO  Giovanni CAPPELLI  Costanza BOSSI  Alessandro BONARI  Giulio ARCANGELI
Institution:Department of Experimental and Clinical Medicine, University of Florence, I-50141 Florence, Italy
Abstract:Long-term indoor-air limit for formaldehyde stipulated by the European Commission is 1 μg/m3, while the World Health Organization has set a threshold of 100 μg/m3 that should not be exceeded for more than 30 min. To date, however, only a few analytical techniques have been developed that can be used to detect formaldehyde at these very restrictive limits. Thus, there is a need to develop for comprehensive methods for analyzing airborne formaldehyde and other carbonyl pollutants in the ambient environment. The aim of this study is to develop a highly sensitive online automated preconcentration gas chromatographic method using large-volume injection with a programmed temperature vaporization injector for the analysis of airborne formaldehyde and ten other carbonyl compounds. The influence of several parameters, such as the maximum volume injected, programmed temperature vaporization transfer time and temperature, carrier gas flow rate, and type of packing material was investigated. After optimization, highly satisfactory results in terms of the absolute and methodological detection limits were achieved, i. e. as low as the μg/m3 level for all the carbonyl pollutants studied. A commercially available sampler, originally designed for active sampling, was evaluated as a passive sampling device; this optimized technique was applied to monitor the concentrations of carbonyl pollutants in the indoor air of ten public buildings in Florence. The strength of this methodology lies both in the low detection limits reached in the simultaneous analysis of a wide group of 2,4-dinitrophenylhydrazine derivatives, and the potential adaptability of this method to other gas chromatographic applications to achieve lower sensitivity.
Keywords:large volume injection (LVI)  gas chromatography (GC)  formaldehyde  passive sampler  airborne carbonyl compounds  programmed temperature vaporization injector
本文献已被 CNKI 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号