首页 | 本学科首页   官方微博 | 高级检索  
     


Chemiluminometric determination of carvedilol in a multi-pumping flow system
Authors:Pires Cherrine K  Marques Karine L  Santos João L M  Lapa Rui A S  Lima José L F C  Zagatto Elias A G
Affiliation:a REQUIMTE, Faculdade de Farmácia da, Universidade do Porto, Rua Aníbal Cunha, 164, 4099-030 Porto, Portugal
b Centro de Energia Nuclear na Agricultura, Universidade de S. Paulo, Piracicaba, São Paulo 13400-970, Brazil
Abstract:In this work a simple, fast, sensitive and selective flow-based procedure for the chemiluminometric determination of carvedilol, a recent non-cardioselective β-blocker with noteworthy antioxidant activity, is proposed. The developed methodology takes advantage of the antioxidant capacity of carvedilol to inhibit the chemiluminescence response resulting from the oxidation of luminol by hypochlorite, by acting as a hypochlorite scavenger. The analytical process was implemented in a multi-pumping flow system that employs multiple solenoid actuated micro-pumps as the only active components. These acted as solution insertion, propelling and commuting units assuring an easily controlled, low cost, compact and reliable analytical system.A linear working range for carvedilol concentrations ranging from 1.2 × 10−7 to 3.0 × 10−6 mol l−1 (r > 0.999, n = 6), was obtained, with a detection limit of 8.7 × 10−9 mol l−1. The system handles about 65 samples per hour yielding precise results (R.S.D. < 1.3%, n = 10). Recoveries within 95 and 104% were obtained.
Keywords:Multi-pumping flow system   Chemiluminescence   Carvedilol   Luminol
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏