首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of arsenic(V) in freshwaters by flow injection with luminol chemiluminescence detection
Authors:Attiq-Ur-Rehman  Mohammad Yaqoob    Abdul Nabi
Institution:Department of Chemistry , University of Balochistan , Quetta, Pakistan
Abstract:A simple and rapid flow injection (FI) method is reported for the determination of arsenic(V) based on luminol chemiluminescence (CL) detection. The molybdoarsenic heteropoly acid formed by arsenic and ammonium molybdate in the presence of ammonium vanadate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The limit of detection was 0.15 μg L?1, with a sample throughput 120 h?1. A linear calibration graph was obtained over the range 0.15 to 7.5 μg L?1 (r 2 = 0.9989; n = 9) with relative standard deviation (n = 4) in the range 0.8 to 2.5%. Interfering cations were removed by passing the sample through an in-line iminodiacetate chelating column and phosphate (at 0.6 mg L?1) was removed off-line by magnesium-induced coprecipitation (MAGIC) method. The method was applied to freshwater samples and the results obtained were in reasonable agreement with the results obtained using HGAAS as the reference method.
Keywords:flow injection analysis  chemiluminescence  arsenate  heteropoly acid  freshwaters