Comparison of wet microwave digestion methods of plant materials for the determination of metals by flame atomic absorption spectrometry
Authors:Stanis?aw Walas  Ma?gorzata Wójtowicz  Halina Mrowiec  Waldemar Zegar
Institution:1. Jagiellonian University , Faculty of Chemistry , Ingardena 3, 30-060 Kraków, Poland walas@chemia.uj.edu.pl;3. Academy of Mining and Metallurgy , Faculty of Fuels and Energy , Mickiewicza 30, 30-059 Krakow, Poland;4. Jagiellonian University , Faculty of Chemistry , Ingardena 3, 30-060 Kraków, Poland
Abstract:Microwave closed-system wet digestion procedures for plant samples were examined. Each procedure was tested with samples of tobacco and cabbage, and included digestion by the use of different acids composition, almost complete evaporation of the digest, and then dissolution of the residue in 1% nitric acid. Three microwave digestion programs that varied power, duration, and temperature were used. Closed-vessel reactions followed open-vessel reaction-delay time. Using flame atomic absorption spectrometry on the digests, four or five elements were determined to evaluate effectiveness, precision and accuracy of analytes extraction into solution. After a preliminary study of tobacco digests, the four most effective procedures were chosen, and detailed investigations were carried out on both tobacco and cabbage reference materials. Although all four of the final procedures were accurate, the most precise procedure, with the lowest errors of determination, was using reverse ‘aqua regia’ for tobacco and ‘aqua regia’ for cabbage.
Keywords:Digestion  Wet microwave procedures  Plant materials  Flame atomic absorption spectrometry
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号