首页 | 本学科首页   官方微博 | 高级检索  
     


Pre-concentration of trace amounts of manganese in water samples based on (1-(2-pyridylazo)-2-naphthol) modified magnetic nanoparticles
Authors:Mostafa Khajeh  Esmael Sanchooli
Affiliation:1. Department of Chemistry , University of Zabol , PO Box 98615-538, Zabol , Iran m_khajeh@uoz.ac.ir;3. Department of Chemistry , University of Zabol , PO Box 98615-538, Zabol , Iran
Abstract:A simple procedure based on magnetic nanoparticles has been developed for analytical purposes. In this method, 1-(2-pyridylazo)-2-naphthol (PAN)-modified magnetic nanoparticles (MNPs) were used for separation and pre-concentration of manganese(II) ions from aqueous samples. This method combines the use of a solution solvent with separation of magnetic nanoparticles from sample solution using a magnet. The influence of different parameters, such as amount of extractant (PAN) loaded on the nanoparticles, pH of solution, adsorption time, amount of modified nanoparticle, type and amount of eluents for desorption of manganese from magnetic nanoparticles were evaluated. The effect of various cationic and anionic interferences on the percentage recovery of manganese was also studied. Manganese ions were adsorped from a solution at pH 9.5 and desorbed from nanoparticles with 10?mL of DMSO?:?HNO3 (1?:?1, v/v). The detection limit of the proposed method was found to be 0.11?µg?L?1. The method was employed to recover and determine the level of manganese in different water samples.
Keywords:manganese  magnetic nanoparticle  (1-(2-pyridylazo)-2-naphthol)  determination  water samples