Use of CT scans and treatment planning software for validation of the dose component of food irradiation protocols
Authors:Joseph Borsa  Rod Chu  Jiansheng Sun  Nick Linton  Craig Hunter
Institution:

MDS Nordion, 447 March Road, Kanata, Ontario, Canada K2K 1X8

Abstract:The challenging problem of estimating the dose delivered to heterogeneous products by radiation modalities of limited penetration can be readily handled by using technologies developed for, and widely used in, radiation therapy applications. In particular, combining CT scanning with radiation treatment planning programs can simulate radiation processing with either photons or electrons, and can provide detailed, high resolution and accurate dose maps for any arbitrary product and package configuration. Such dose maps are an essential part of process validation. Comparison of the simulated dose distributions with measured dose maps verifies the soundness of this approach. The present communication presents results obtained with the simulation technique for a variety of common food items which are likely candidates for radiation processing.
Keywords:Dosimetry  Food irradiation  Cobalt-60  Electron beam  Process validation