首页 | 本学科首页   官方微博 | 高级检索  
     

Preconcentration and separation of trace Pd(II) and Pt(IV) with silica gel bonded by aminopropyl-benzoylazo-4-(2-pyridyl-azo)-resorcinol
引用本文:刘锋,李克安,陈文,吴燕升,姚团利,童沈阳. Preconcentration and separation of trace Pd(II) and Pt(IV) with silica gel bonded by aminopropyl-benzoylazo-4-(2-pyridyl-azo)-resorcinol[J]. 中国化学, 2000, 18(4): 537-541. DOI: 10.1002/cjoc.20000180415
作者姓名:刘锋  李克安  陈文  吴燕升  姚团利  童沈阳
基金项目:Project (No. 2932009) supported by the Natural Science Foundation of Beijing.
摘    要:This paper reports a simple and highly selective method for preconcentrating and separating of trace Pd(II) and Pt(IV) with silica gel bonded by aminopropyl-benzoylazo-4-(2-pyridy-lazo)-resorcinol (ABPR-SG). ABPR-SG is stable in solution from 6 mol/L HCl to pH 7.0 and in common organic solvents. The maximum adsorptive capacity of Pd(n) on ABPR-SG is 362 μmol/g. After preconcentration and separation by using ABPR-SG column, Pd(II) and Pt(IV) of μg/L level in artificial water samples can be measured reliably by common spedrophotometry. The maximum concentration factors of Pd(II) and Pt(IV) on ABPR-SG column are 143 and 125 respectively. The chromatographic column packed with ABPR-SG can be reused. The method is simple and efficient.


Preconcentration and separation of trace Pd(II) and Pt(IV) with silica gel bonded by aminopropyl-benzoylazo-4-(2-pyridyl-azo)-resorcinol
Lhj Feng Li,Ke‐An,Chen Wen,Wu Yan‐Sheng,Yao Tuan‐Li,Tong Shen‐Yang. Preconcentration and separation of trace Pd(II) and Pt(IV) with silica gel bonded by aminopropyl-benzoylazo-4-(2-pyridyl-azo)-resorcinol[J]. Chinese Journal of Chemistry, 2000, 18(4): 537-541. DOI: 10.1002/cjoc.20000180415
Authors:Lhj Feng Li  Ke‐An  Chen Wen  Wu Yan‐Sheng  Yao Tuan‐Li  Tong Shen‐Yang
Abstract:This paper reports a simple and highly selective method for preconcentrating and separating of trace Pd(II) and Pt(IV) with silica gel bonded by aminopropyl‐benzoylazo‐4‐(2‐pyridylazo)‐resorcinol (ABPR·SG). ABPR·SG is stable in solution from 6 mol/L HCl to pH 7.0 and in common organic solvents. The maximum adsorptive capacity of Pd(II) on ABPRSG is 362 μmol/g. After preconcentrating and separation by using ABPR·SG column, Pd(II) and Pt(IV) of μg/L level in artificial water samples can be measured reliably by common spectrophotometer. The maximum concentration factors of Pd(II) and Pt(IV) on ABPR·SG column are 143 and 125 respectively. The chromatographic column packed with ABPR·SG can be reused. The method is simple and efficient.
Keywords:Preconcentration   separation   ABPR    SG   spec-trophotometry