首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurement of laminar,transitional and turbulent pipe flow using Stereoscopic-PIV
Authors:C W H van Doorne  J Westerweel
Institution:(1) J.M. Burgers Center for Fluid Dynamics, Laboratory for Aero- and Hydrodynamics, Delft University of Technology, Leeghwaterstraat 21, 2628 CA Delft, The Netherlands;(2) Present address: Shell Global Solutions International BV, P.O. Box 38000, 1030 BN Amsterdam, The Netherlands
Abstract:Stereoscopic particle image velocimetry (SPIV) is applied to measure the instantaneous three component velocity field of pipe flow over the full circular cross-section of the pipe. The light sheet is oriented perpendicular to the main flow direction, and therefore the flow structures are advected through the measurement plane by the mean flow. Applying Taylor’s hypothesis, the 3D flow field is reconstructed from the sequence of recorded vector fields. The large out-of-plane motion in this configuration puts a strong constraint on the recorded particle displacements, which limits the measurement accuracy. The light sheet thickness becomes an important parameter that determines the balance between the spatial resolution and signal to noise ratio. It is further demonstrated that so-called registration errors, which result from a small misalignment between the laser light sheet and the calibration target, easily become the predominant error in SPIV measurements. Measurements in laminar and turbulent pipe flow are compared to well established direct numerical simulations, and the accuracy of the instantaneous velocity vectors is found to be better than 1% of the mean axial velocity. This is sufficient to resolve the secondary flow patterns in transitional pipe flow, which are an order of magnitude smaller than the mean flow.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号