首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Transmission and fractionation of micro-sized particle suspensions
Authors:G Brans  A van Dinther  B Odum  CGPH Schroën  RM Boom
Institution:

aFood and Bioprocess Engineering Group, Wageningen University, P.O. Box 8129, 6700 EV Wageningen, The Netherlands

Abstract:In processes aimed at the fractionation of a multi-component feed stream, transmission of particles through the membrane is at least as important as retention of larger particles. In this paper, we describe the mechanisms of transmission of mono-disperse latex particles through a polymer membrane. The effects of process parameters, such as transmembrane pressure, cross flow velocity and feed concentration were investigated. In dead end filtration mode, we found that, depending on the transmembrane pressure, four particle transmission regimes could be distinguished.

Particle deposition on polymer membranes and polymer microsieves was investigated in-line with confocal scanning laser microscopy (CSLM). It was observed that with the polymer membrane random depth deposition took place, while the microsieve exhibited in-pore fouling.

In addition, bi-disperse particle suspensions were fractionated with dead end and cross flow membrane filtration, and various effects were charted. Based on the phenomena observed, it is concluded that the design of a fractionation process starts with defining a stable transmission regime for small particles, and subsequently choosing the process conditions for minimal deposition of the larger particles.

Keywords:Microfiltration  Particle separation  Membrane  Microsieve  CSLM
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号