首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Analysis of solid samples by ICP-mass spectrometry
Authors:Uwe Voellkopf  M Paul and E R Denoyer
Institution:(1) Bodenseewerk, Perkin-Elmer GmbH, Postfach 101164, W-7770 Überlingen, Federal Republic of Germany;(2) The Perkin Elmer Corporation, 761 Main Avenue, 06859 Norwalk, CT, USA
Abstract:Summary ICP-Mass spectrometry is typically used as a technique for very rapid multielement analysis at trace and ultra-trace levels of solutions by continuous sample aspiration and nebulization. However, ICP-MS is well suited to be used as a detector for other sample introduction devices. For the analysis of solid samples laser sampling and electrothermal vaporization accessories may be used as sample introduction devices for ICP-MS. Laser sampling permits the analysis of many different types of solid materials. For solid sampling ETV-ICP-MS analysis it is of advantage to reduce the sample to a fine powder prior to analysis. For automated analysis powders may be introduced as slurries into the graphite furnace by means of a slurry sampling device. Since appropriate certified solid reference materials are not always available for calibration, or since they are not certified for all analyte elements of interest, the analyses discussed in this contribution were performed semiquantitatively. The instrument response function was established using reference materials which were similar in their composition to the samples. The results of semiquantitative bulk analyses of glass (NIST 612) and geological material (USGS GXR-3) by laser sampling ICP-MS are in good agreement with the certified values. The concentrations of the analytes determined in the glass sample were in the range of 10 mgrg/g to 80 mgrg/g. The lowest analyte concentration in the geological sample was 0.4 mgrg/g (Eu) and the highest was approximately 186 mg/g (Fe). The precision achieved was in the order of 5% to 15%. Laser sampling ICP-MS is not only suitable to bulk analysis but also to analyses where spatial information is required. As an example for such an application the determination of Pb in a wine bottle cork stopper is dicussed. The slurry sampling technique was used for the semiquantitative analysis of NIST coal reference samples by electrothermal vaporization ICP-MS. The accuracy achieved with this approach was within a factor of ±2 of the reference values.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号