首页 | 本学科首页   官方微博 | 高级检索  
     检索      

相干布居数囚禁原子频标的实现及相关实验参数研究
引用本文:杜润昌,刘国宾,陈杰华,王谨,刘朝阳,顾思洪.相干布居数囚禁原子频标的实现及相关实验参数研究[J].光谱学与光谱分析,2008,28(8):1697-1700.
作者姓名:杜润昌  刘国宾  陈杰华  王谨  刘朝阳  顾思洪
作者单位:中国科学院武汉物理与数学研究所,湖北,武汉,430071;中国科学院研究生院,北京,100039;中国科学院武汉物理与数学研究所,湖北,武汉,430071;中国科学院武汉物理与数学研究所,湖北,武汉,430071;中国科学院冷原子物理中心,湖北,武汉,430071
基金项目:国家自然科学基金,国家重点基础研究发展计划(973计划)
摘    要:原子频标要求高信噪比和窄线宽的鉴频信号,但对于被动型相干囚禁态原子频标(CPT频标), 改善鉴频信号信噪比以增加线宽为代价,因此选择合适的信噪比和线宽组合是研制CPT原子频标频标的重要环节。文章介绍了用桌面CPT频标系统地研究了鉴频信号与温度、光强等参数的关系所获得的研究结果,由此获得了合适选取的信噪比与线宽组合的依据。文章还给出了关于光源非理想偏振导致的消相干效应对CPT频标的影响所开展的实验结果。文章所提供的研究结果不仅帮助我们研制成功了CPT频标,而且对于CPT物理现象研究和其他CPT频标的研制也有参考价值。

关 键 词:相干布居数囚禁  原子频标  铷原子
收稿时间:2007-03-28

Realization and Investigation of Relative Experimental Parameter of Coherent Population Trapping Frequency Standard
DU Run-chang,LIU Guo-bin,CHEN Jie-hua,WANG Jin,LIU Chao-yang,GU Si-hong.Realization and Investigation of Relative Experimental Parameter of Coherent Population Trapping Frequency Standard[J].Spectroscopy and Spectral Analysis,2008,28(8):1697-1700.
Authors:DU Run-chang  LIU Guo-bin  CHEN Jie-hua  WANG Jin  LIU Chao-yang  GU Si-hong
Institution:1.Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China2.Graduate School of Chinese Academy of Sciences, Beijing 100039, China3.Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
Abstract:It is desirable for an atomic frequency standard that clock transition signal is of both high S/N rate and narrow linewidth.While for a passive coherent population trapping(CPT) frequency standard,increasing S/N rate is at the expense of en-widened lidnewidth,therefore it is crucial to choose a proper combination of S/N rate and linewidth.The present paper presents the experimental results of our systematically study on the relations between clock transition signal and parameters such as temperature and laser intensity with an optical table top CPT frequency standard.The obtained results provide us the criterion of choosing the combination of S/N rate and lidnewidth.The paper also presents experimental study results of de-coherent effect caused by unperfect circular polarization laser.Those experimental results were the good reference in the realization of CPT frequency standard,and they are also the general reference to CPT phenomenon and CPT frequency standard studies.
Keywords:Coherent population trapping  Atomic frequency standard  Rubidium atoms
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号