共沉淀分离富集—ICP-AES法测定高纯钨酸钠中痕量铍钪镱锌
引用本文:马晓国,成晓玲.共沉淀分离富集—ICP-AES法测定高纯钨酸钠中痕量铍钪镱锌[J].分析测试技术与仪器,1998,4(2):116-119.
作者姓名:马晓国  成晓玲
作者单位:广东工业大学分析测试中心
摘    要:以La(OH)3为共沉淀剂,使高纯Na2WO4中痕量Be,Sc,Yb,Zn与基体相分离并富集,然后用ICP-AES法测定,实验表明,发PH为12时,用6mL%1%La溶液进行两次共沉淀淀分离能使上述元素定量分离回收,回收率为92.7%-102.5%,相对标准偏差为2.8-5.9%。

关 键 词:共沉淀  ICP  AES  钨酸钠分析        
收稿时间:4/1/1998 12:00:00 AM
修稿时间:1998/5/12 0:00:00

Simultaneous Determination of Trace Beryllium, Scandium, Ytterbium and Zinc in High-purity Sodium Tungstate by Coprecipitation and ICP-AES
Ma Xiaoguo and Cheng Xiaoling.Simultaneous Determination of Trace Beryllium, Scandium, Ytterbium and Zinc in High-purity Sodium Tungstate by Coprecipitation and ICP-AES[J].Analysis and Testing Technology and Instruments,1998,4(2):116-119.
Authors:Ma Xiaoguo and Cheng Xiaoling
Institution:Analysis and Testing Center, Guangdong University of Technology, Guangzhou 510090;Analysis and Testing Center, Guangdong University of Technology, Guangzhou 510090
Abstract:
Keywords:coprecipitation\ separation and concentration\ ICP  AES\ sodium tungstate beryllium scandium\ ytterbium\ zinc  