首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of WR-1065 and WR-33278 by liquid chromatography with electrochemical detection
Authors:Pendergrass James A  Srinivasan Venkataraman  Kumar K Sree  Jackson William E  Seed Thomas M
Institution:Armed Forces Radiobiology Research Institute, Radiation Medicine Department, Bethesda, MD 20889-5603, USA. pendergrass@afrri.usuhs.mil
Abstract:A liquid chromatographic method using electrochemical detection is presented for measuring the thiol WR-1065 12-(3-aminopropylamino) ethanethiol] and its symmetrical disulfide WR-33278 NH2(CH2)3NHCH2CH2S]2. WR- 1065 is the active, radioprotective drug derived from the phosphorothioate pro-drug WR-2721 (amifostine). External standard curves for both compounds were linear over the range of 40-200 pmol injected (r2 = 0.999 and 0.996 for the thiol and disulfide, respectively). The detection and quantitation limits for WR-1065 were 9 and 18 pmol, respectively, whereas the corresponding values for WR-33278 were 30 and 59 pmol, respectively. Within- and between-day determinations of measurement Vision and accuracy for both compounds validated the suitability of this assay method.
Keywords:
本文献已被 PubMed 等数据库收录!