Readout electronics testing of the CMS Tracker modules with LT setup |
| |
Authors: | K. Sogut |
| |
Affiliation: | (1) Department of Physics, University of Cukurova, Balcali, Adana, Turkey |
| |
Abstract: | The tracking part of the CMS detector will be built with ∼16000 silicon detector modules, and kept at −10°C for the ten years of the operation of the LHC. All the model materials need to be verified of having a good performance at this low temperature, before their installation into the CMS Tracker. In order to track performance quality, assurance tests are done with two different systems. Of the two setups used, the LT system module is the one that is used to identify whether the performance of readout electronics and leakage current flowing on the silicon sensors is affected by low temperature. In this paper a detailed layout of the CMS TOB modules and their front-end hybrids are presented. In addition, the LT testing results of the 190 TOB modules that were produced and tested in 2004 by the FNAL-CMS group are given. The text was submitted by the author in English. |
| |