Authors:V.?O.?Petukhov  author-information"  >  author-information__contact u-icon-before"  >  mailto:v.petukhov@ifanbel.bas-net.by"   title="  v.petukhov@ifanbel.bas-net.by"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,V.?A.?Gorobets,A.?A.?Matsukevich
Affiliation:(1) B. I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, 68 F. Skorina Ave., Minsk, 220072, Belarus
Abstract:A technique of detection of ozone, using a CO2 laser with rapid automated tuning over 8–10 generation lines in the 9.4–9.6-µm spectral range, has been developed. Its experimental verification has shown a higher accuracy of detecting low concentrations of O3 in comparison with the traditional technique of differential absorption on two lines (on-line and off-line). Using the technique suggested, the content of ozone in the vicinity of city roads with heavy traffic has been measured.__________Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 72, No. 2, pp. 251–255, March–April, 2005.