首页 | 本学科首页   官方微博 | 高级检索  
     检索      


On the blast resistance of laminated glass
Authors:PA Hooper  RAM Sukhram  BRK Blackman  JP Dear
Institution:1. Imperial College London, Department of Mechanical Engineering, Exhibition Road, London SW7 2AZ, United Kingdom;2. Arup, 13 Fitzroy Street, London W1T 4BQ, United Kingdom
Abstract:Blast resistant glazing systems typically use laminated glass to reduce the risk of flying glass debris in the event of an explosion. Laminated glass has one or more bonded polymer interlayers to retain glass fragments upon fracture. With good design, the flexibility of the interlayer and the adhesion between layers enable laminated glass to continue to resist blast after the glass layers fracture. This gives protection from significantly higher blast loads when compared to a monolithic pane. Full-scale open-air blast tests were performed on laminated glass containing a polyvinyl butyral (PVB) interlayer. Test windows of size 1.5 m × 1.2 m were secured to robust frames using structural silicone sealant. Blast loads were produced using charge masses of 15 kg and 30 kg (TNT equivalent) at distances of 10–16 m. Deflection and shape measurements of deforming laminated glass were obtained using high-speed digital image correlation. Measurements of loading at the joint, between the laminated glass and the frame, were obtained using strain gauges. The main failure mechanisms observed were the cohesive failure of the bonded silicone joint and delamination between the glass and interlayer at the pane edge. A new finite element model of laminated glass is developed and calibrated using laboratory based tests. Predictions from this model are compared against the experimental results.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号