首页 | 本学科首页   官方微博 | 高级检索  
     


A Novel Label-free Chronoamperometric Immunosensor Based on a Biocomposite Material for Rapid Detection of Carcinoembryonic Antigen
Authors:Chochanon Moonla  Suphaporn Chenkhuruthum  Tik Ouiram  Anchana Preechaworapun  Weerinradah Tapala  Kamonwad Ngamchuea  Tanin Tangkuaram
Affiliation:1. Applied Chemistry Program, Faculty of Science, Maejo University, 50290 Chiang Mai, Thailand;2. Applied Chemistry Program, Faculty of Science, Maejo University, 50290 Chiang Mai, Thailand

National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), 12120 Pathumthani, Thailand;3. Chemistry Program, Faculty of Science and Technology, Pibulsongkram Rajabhat University, 65000 Phitsanulok, Thailand;4. School of Chemistry, Institute of Science, Suranaree University of Technology, 30000 Nakhon Ratchasima, Thailand

Abstract:In this research, poly(diallyldimethylammonium chloride)-capped gold nanoparticles, nickel ferrite particles, and carbon nanotubes were combined to form a PANC metal composite. The prepared metal composite modified onto a glassy carbon electrode was electropolymerized with poly(o-phenylenediamine) and immobilized with horseradish peroxidase, anti-carcinoembryonic antigen antibody, and bovine serum albumin to create the label-free immunosensors for rapid detection of carcinoembryonic antigen (CEA) using chronoamperometry. This developed biocomposite material modified onto a glassy carbon electrode presented an excellent electrocatalytic response to the redox reaction of hydrogen peroxide as a sensing probe, from which the kinetic parameters including of a charge transfer rate constant, a diffusion coefficient value, an electroactive surface area, and a surface concentration were calculated to be 1.85 s−1, 4.28×10−6 cm2 s−1, 0.14 cm2 and 1.87×10−8 mol cm−2, respectively. The developed immunosensors also exhibited a wide linear range of CEA concentration from 0.01 to 25 ng mL−1 with high sensitivity (96.21 μA cm−2 ng−1 mL) and low detection limit (0.72 pg mL−1), excellent selectivity without interfering effects from possible species (amoxicillin, ascorbic acid, aspirin, caffeine, cholesterol, dopamine, glucose, and uric acid), outstanding stability (n=100, %I>50 %), repeatability (%RSD=0.34, n=10), reproducibility (%RSD=4.06, n=10), and rapid analysis (25 s each operation time). This proposed method was successfully applied for CEA detection in whole blood samples with satisfactory results, suggesting that this developed sensing platform may be considered to be exploited for fabrication of other label-free electrochemical immunosensors for the real sample analysis.
Keywords:Label-free immunosensors  Chronoamperometric immunosensors  CEA immunosensors  Biocomposite material  Carcinoembryonic antigen
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号