首页 | 本学科首页   官方微博 | 高级检索  
     

基于纳米结构的电化学传感器用于伏安法测定苄丝肼、尿酸和叶酸(英文)
引用本文:Sakineh Esfandiari Baghbamidi,Hadi Beitollahi,Seyed Zia Mohammadi,Somayeh Tajik,Somayeh Soltani-Nejad,Vahhab Soltani-Nejad. 基于纳米结构的电化学传感器用于伏安法测定苄丝肼、尿酸和叶酸(英文)[J]. 催化学报, 2013, 34(10): 1869-1875. DOI: 10.1016/S1872-2067(12)60655-X
作者姓名:Sakineh Esfandiari Baghbamidi  Hadi Beitollahi  Seyed Zia Mohammadi  Somayeh Tajik  Somayeh Soltani-Nejad  Vahhab Soltani-Nejad
作者单位:Islamic Azad University,Bandar Abbas Branch;Environment Department,Institute of Science and High Technology and Environmental Sciences,Graduate University of Advanced Technology;Department of Chemistry,Payame Noor University;Department of Chemistry,Shahid Bahonar University of Kerman;Young Researchers Society,Shahid Bahonar University of Kerman;Department of Chemistry,Islamic Azad University,North Tehran Branch
摘    要:A carbon paste electrode modified with carbon nanotubes and ferrocene was fabricated.An electrochemical study of the modified electrode and an investigation into its efficiency for the electrocatalytic oxidation of benserazide,uric acid and folic acid were undertaken.The electrode was also used to study the electrocatalytic oxidation of benserazide using cyclic voltammetry,chronoamperometry,and square wave voltammetry(SWV).We found that the oxidation of benserazide at the surface of the modified electrode occurs at a potential about 285 mV lower than that of unmodified carbon paste electrode.SWV gave a linear dynamic range from 8.0×10-7 to 7.0×10 4 mol/L.The detection limit was 1.0×10-7 mol/L for benserazide.This modified electrode was used for the determination of benserazide,uric acid,and folic acid in an urine sample.

关 键 词:Benserazide  Uric acid  Folic acid  Carbon nanotube  Carbon paste electrode
收稿时间:2013-06-04

Nanostructure-based electrochemical sensor for the voltammetric determination of benserazide,uric acid,and folic acid
Sakineh Esfandiari Baghbamidi;Hadi Beitollahi;Seyed Zia Mohammadi;Somayeh Tajik;Somayeh Soltani-Nejad;Vahhab Soltani-Nejad;Islamic Azad University,Bandar Abbas Branch;Environment Department. Nanostructure-based electrochemical sensor for the voltammetric determination of benserazide,uric acid,and folic acid[J]. Chinese Journal of Catalysis, 2013, 34(10): 1869-1875. DOI: 10.1016/S1872-2067(12)60655-X
Authors:Sakineh Esfandiari Baghbamidi  Hadi Beitollahi  Seyed Zia Mohammadi  Somayeh Tajik  Somayeh Soltani-Nejad  Vahhab Soltani-Nejad  Islamic Azad University,Bandar Abbas Branch  Environment Department
Affiliation:Department of Chemistry,Payame Noor University;Department of Chemistry,Shahid Bahonar University of Kerman;Young Researchers Society,Shahid Bahonar University of Kerman;Department of Chemistry,Islamic Azad University,North Tehran Branch;
Abstract:A carbon paste electrode modified with carbon nanotubes and ferrocene was fabricated. An electrochemical study of the modified electrode and an investigation into its efficiency for the electrocatalytic oxidation of benserazide, uric acid and folic acid were undertaken. The electrode was also used to study the electrocatalytic oxidation of benserazide using cyclic voltammetry, chronoamperometry, and square wave voltammetry (SWV). We found that the oxidation of benserazide at the surface of the modified electrode occurs at a potential about 285 mV lower than that of unmodified carbon paste electrode. SWV gave a linear dynamic range from 8.0×10-7 to 7.0×10-4 mol/L. The detection limit was 1.0×10-7 mol/L for benserazide. This modified electrode was used for the determination of benserazide, uric acid, and folic acid in an urine sample.
Keywords:Benserazide  Uric acid  Folic acid  Carbon nanotube  Carbon paste electrode
本文献已被 CNKI ScienceDirect 等数据库收录!
点击此处可从《催化学报》浏览原始摘要信息
点击此处可从《催化学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号