首页 | 本学科首页   官方微博 | 高级检索  
     


Direct spectrophotometric determination of ruthenium in aqueous streams of nuclear reprocessing
Authors:S. Ganesh  P. Velavendan  N. K. Pandey  U. Kamachi Mudali  R. Natarajan
Affiliation:1. Reprocessing Research and Development Division, Reprocessing Group Indira Gandhi Centre for Atomic Research, Kalpakkam, 603102, India
Abstract:A fiber optic aided spectrophotometric technique has been developed for determination of ruthenium in nitric acid medium. The developed method is simple, accurate and applicable to aqueous streams of nuclear reprocessing. The system obeys Lambert–Beer’s law at 468 nm in the concentration range of 30–360 μg/mL of ruthenium. The molar absorption coefficient, detection limit and Sandell’s sensitivity are 68.477 L Mol?1 cm?1, 31 μg/mL and 0.0124 μg/cm2 respectively. Relative standard deviation was less than 2 % and correlation coefficient was 0.9998. The results obtained by the developed procedure are in good agreement with those obtained by the standard ICP-OES method. Fission products like zirconium and strontium are not interfering. Uranium is interfering and needs prior separation by solvent extraction method. The developed method is adaptable for remote operation and on-line monitoring.