Electrochemical Sensing Platform Integrated with Solid-state Reference Electrode Based on Indium Tin Oxide Interdigitated Array Electrodes
Authors:Je Hyun Bae  Hyeri Jeon  Hyun Ju Yang  Chung Mu Kang  Donghoon Han
Institution:1. Graduate School of Analytical Science and Technology (GRAST), Chungnam National University, Daejeon, 34134 Republic of Korea;2. Department of Chemistry, The Catholic University of Korea, Bucheon, Gyeonggi-do, 14662 Republic of Korea;3. Electrochemistry Laboratory, Advanced Institutes of Convergence Technology, Suwon, Gyeonggi-do, 16229 Republic of Korea
Abstract:We present a new strategy for the fabrication of a fully integrated electrochemical platform. The three-electrode system consists of an indium tin oxide interdigitated array as working electrode, a solid-state reference electrode, and an electrodeposited Pt counter electrode that are placed in microfluidic channel. By controlling the electrodeposition conditions, such as the applied potential and time, the stability and uniformity of the films can be optimized. A solid-state reference electrode was fabricated on the nanoporous Pt via electropolymerization of poly-1,3-phenylenediamine. This system provides a simple method for the fabrication of three-electrode system and opens the possibility for an electroanalytical platform.
Keywords:Electrochemical platform  three-electrode system  microchip  interdigitated electrode array  solid-state reference electrode