首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simple test kit based on colorimetry for quantification of magnesium content in natural rubber latex by miniaturized complexometric titration without using masking agent
Institution:1. Department of Chemistry and Center of Excellent for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand;2. Department of Chemistry and Center of Excellent for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Road, Bangkok 10400, Thailand;1. Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi”, University of Bologna, Viale Risorgimento 2, Bologna, 40136, Italy;2. Department of Civil, Chemical, Environmental, and Materials Engineering, University of Bologna, Via Terracini 28, Bologna, 40131, Italy;3. Department of Industrial Chemistry “Toso Montanari”, University of Bologna, Viale Risorgimento 4, Bologna, 40136, Italy;1. Department of Polymer Science & Engineering, Hannam University, Daejeon 34054, Republic of Korea;2. Underground Solutions Inc., Poway, CA 92064, USA;3. Ansco Inc., Daejeon 34051, Republic of Korea;1. Toray Research Center, Inc., Otsu, 520-8567, Japan;2. Application R&D Center, Horiba Ltd., Kyoto, 601-8510, Japan;3. Rakuyo Giken Co., Ltd., Kumiyama-cho, Kyoto, 613-0023, Japan;4. Graduate School of Science, Hiroshima University, Higashihiroshima, 739-8526, Japan
Abstract:A simple, low-cost and portable field test kit based on colorimetry with detection by naked eye was developed for determination of magnesium content in natural rubber latex (NRL). The miniaturized complexometric titration between Mg2+ and EDTA without any masking agent was a key reaction in this development, which was designed according to the concept of green chemistry by reduction of waste generation and chemical and time consumption. The system enabled quantification of magnesium content in NRL at low concentration with the detection limit being <50 mg L−1, small sample volume uptake (0.18 g, sampling by a small spoon) and use of <1.5 mL reagent volume which was >70 times less than that applied in the conventional method. Moreover, with the presence of potential interference ions, greater selectivity towards magnesium was observed. Furthermore, the reagents used in our developed test kit were stable for >6 months at room temperature. The results obtained on real samples were in agreement with those obtained from the conventional complexometric titration (ISO 17403: 2014(E)) method. The proposed technique provides a low-cost, rapid, simple, selective and on-site analysis of magnesium content in NRL.
Keywords:Test kit  Natural rubber latex (NRL)  Green chemistry  Complexometric titration
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号