首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of myoglobin in human serum by high-performance liquid chromatography with chemiluminescence detection
Authors:V G Maltsev  T M Zimina  A B Khvatov  B G Belenkii
Abstract:A highly sensitive method for the determination of myoglobin in serum is described, based on high-performance size-exclusion chromatography with chemiluminescence detection. Serum proteins are separated according to their molecular masses on columns packed with TSK-SW gel and those containing haem are detected selectively by post-column chemiluminescence reaction with luminol using a conventional fluorimetric detector. The method is rapid (30 min) and sufficiently sensitive for the diagnosis of myocardial infarction. The minimum detectable myoglobin concentration is 10 ng/ml.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏