Tritium gas handling system for muon catalyzed fusion research at RIKEN-RAL muon facility |
| |
Authors: | T Matsuzaki K Nagamine M Tanase M Kato K Kurosawa K Ishida SN Nakamura I Watanabe GH Eaton |
| |
Institution: | (1) Muon Science Laboratory, The Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198, Japan;(2) High Energy Accelerator Research Organization (KEK-MSL), Meson Science Laboratory, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan;(3) Department of Radioisotopes, Japan Atomic Energy Research Institute (JAERI), 2-4 Shirane, Tokaimura, Ibaraki 319-1106, Japan;(4) Rutherford Appleton Laboratory (RAL), ISIS Muon Facility, Chilton, Didcot, Oxon, OX11 0QX, UK |
| |
Abstract: | For muon catalyzed fusion (μCF) experiments at RIKEN-RAL muon facility, a tritium gas handling system for a high purity D–T
target, free from 3 component, has been constructed to perform precise measurements of α-sticking probability in the μCF cycle. The system has
been constructed to enable us to purify the target D–T gas by removing 3He component, to adjust the D/T mixing ratio, and to measure the hydrogen isotope components at the experiment site. The whole
performance has been confirmed and a tritium gas with the inventory of 56 TBq (1500 Ci) has been operated in the system.
This revised version was published online in August 2006 with corrections to the Cover Date. |
| |
Keywords: | tritium gas handling system |
本文献已被 SpringerLink 等数据库收录! |
|