首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of As,Cd, Pb,and Hg in urine using inductively coupled plasma mass spectrometry with the direct injection high efficiency nebulizer
Authors:Michael G Minnich  Derek C Miller  Patrick J Parsons
Institution:1. Trace Elements Laboratory, Wadsworth Center, New York State Department of Health, P.O. Box 509, Albany, NY 12201-0509, USA;2. Department of Environmental Health Sciences, School of Public Health, The University at Albany, P.O. Box 509, Albany, NY 12201-0509, USA
Abstract:The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., 40Ar35Cl+ on 75As+ and 98Mo16O+ on 114Cd+) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, especially for analytes such as Hg. The Dynamic Reaction Cell (DRC) is used in this study to attenuate the background level of ArCl+ in spite of the increase in the solvent load and, in turn, the urine matrix (chloride) delivered to the plasma by the LB-DIHEN. This is the first report on coupling the LB-DIHEN to a standard autosampler for unattended sample analysis. The robustness of direct injection nebulization for routine analysis and the issues associated with automation of the sample introduction process are discussed. Although the figures of merit (sensitivity, limit of detection, and precision) determined for both nebulizers are slightly poorer for the LB-DIHEN than for the concentric pneumatic nebulizer, there is not a clinically significant difference between the results for both sample introduction systems. The accuracy of results is assessed using archived urine materials that are circulated by several different proficiency testing (PT) programs and external quality assessment schemes (EQAS). Results obtained using the LB-DIHEN were within the acceptable range established by a consensus pool generated using different methods, none of which are likely to be using direct injection nebulization. Internal quality control sample results obtained using the LB-DIHEN were compared to those obtained using the conventional nebulizer. Reported results were similar for both nebulizers. Thus, these results show that the LB-DIHEN is certainly feasible for the analysis of urine specimens.
Keywords:Inductively coupled plasma mass spectrometry  Direct injection high efficiency nebulizer  Urine  Mercury
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号