首页 | 本学科首页   官方微博 | 高级检索  
     


Highly sensitive spectrophotometric determination of micro amounts of iron with chromai blue G and cetyltrimethylammonium chloride
Authors:Mitsuo Miyawaki  Katsuya Uesugi
Affiliation:(1) Department of Chemistry, Himeji Institute of Technology, Himeji, Japan;(2) Present address: Kobe Technical College, Tarumi, Kobe, Japan
Abstract:Summary A ternary complex between iron(III), Chromal Blue G (C. I. 43835) and cetyltrimethylammonium chloride is proposed for the determination of iron (III). The stoichiometric ratio of iron (III) to Chromai Blue G is 1ratio3. Beer's law is obeyed from 0.04 to 0.4 ppm of iron; the molar absorptivity is 1.43×105 l·mole–1·cm–1. The proposed method has been applied to the determination of iron in a magnesium alloy.
Hochempfindliche spektrophotometrische Bestimmung von Mikromengen Eisen mit Chromctlblau G und Cetyltrimethylammoniumcblorid
Zusammenfassung Zur Bestimmung von Eisen(III) wird ein ternärer Komplex aus Eisen(III), Chromai Blue G (Farbindex 43835) und Cetyltrimethylammoniumchlorid vorgeschlagen. Das stöchiometrische Verhältnis Eisen(III): Chromal Blue G ist 1ratio3. Das Beersche Gesetz gilt von 0,04 bis 0,4 ppm Fe; der Extinktionskoeffizient ist 1,43×105 l·mole–1·cm–1. Die vorgeschlagene Methode dient für die Bestimmung von Eisen in Magnesiumlegierungen.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号