首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Preliminary application of a DGV system using a single intensified camera in a supersonic wind tunnel
Authors:P Wernert  B Martinez
Institution:1. French-German Research Institute of Saint-Louis (ISL), 5, rue du Général Cassagnou, F-68300, Saint-Louis, France
Abstract:A DGV system using a continuous wave Argon laser and an optical arrangement with a single intensified camera has been set up at the ISL blow-down supersonic wind tunnel. The first tests have been performed over a 12.5° 2D wedge at a freestream Mach number of 2. A mean velocity field has been calculated from 28 individual measurements. When compared to the theoretical velocity distribution, deviations of 8 % to 15 % have been obtained. Preliminary tests have also been performed on a missile-like model equipped with a lateral jet system. Individual as well as mean velocity fields are presented.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏