Study on the application of active balancing device to solve the vibration problem for the rotor with bending fault
作者姓名:何立东  Shen  Wei  Gao  Jinji  Zhou  Weihua
作者单位:Beijing University of Chemical Tectmology, Beijing 100029, P.R. China
摘    要:The rotor with bending faults that occurrs on the rotating machinery usually vibrates seriously. This paper investigates to apply the active balancing device on a flexible rotor with bending faults to solve the vibration problem. Two problems are studied by finite element method firstly: Where the balance actuator is fixed on the shaft and how much the balancing capacity of the active balancing device is needed. The experiment is then carried out on the test rig, which consists of a flexible rotor with bending faults. The test results indicate that the bending rotor peak vibration response can be decreased from 550~m to 40~tm below by using the active balancing device. The peak vibration response decreases approximately by 93 %. The synchronous vibration due to the rotor bending faults can be controlled effectively by using ac- tive balancing device. The active balancing device is especially adapted to solve the problem caused by thermal distortion with time-variation and randomness, which is varied with working conditions, thus it has good practical value in practice.

关 键 词:涡轮机  振动  FEA  有限元  动态平衡  挠度
收稿时间:2005-06-01

Study on the application of active balancing device to solve the vibration problem for the rotor with bending fault
He Lidong,Shen Wei,Gao Jinji,Zhou Weihua.Study on the application of active balancing device to solve the vibration problem for the rotor with bending fault[J].High Technology Letters,2006,12(3):225-230.
Authors:He Lidong  Shen Wei  Gao Jinji  Zhou Weihua
Abstract:The rotor with bending faults that occurrs on the rotating machinery usually vibrates seriously. This paper investigates to apply the active balancing device on a flexible rotor with bending faults to solve the vibration problem. Two problems are studied by finite element method firstly: Where the balance actuator is fixed on the shaft and how much the balancing capacity of the active balancing device is needed. The experiment is then carried out on the test rig, which consists of a flexible rotor with bending faults. The test results indicate that the bending rotor peak vibration response can be decreased from 550μm to 40μm below by using the active balancing device. The peak vibration response decreases approximately by 93%. The synchronous vibration due to the rotor bending faults can be controlled effectively by using active balancing device. The active balancing device is especially adapted to solve the problem caused by thermal distortion with time-variation and randomness, which is varied with working conditions, thus it has good practical value in practice.
Keywords:active balancing  bending  turbomachinery  vibration  FEA