摘    要:基于砷、铅、锡、锑、铋与碘离子形成络合物,用MIBK萃取使其与基体分离, 用石墨炉原子吸收光谱法测定了铁镍基高温合金中这五种元素。文章主要对萃取条件及萃取后剩余基体对待测元素的影响进行了研究, 同时采用掩蔽的方法消除了合金中钨、铌、钽的干扰。在所选定的实验条件下,测得砷、铅、锡、锑、铋的回收率范围为93%~99%;相对标准偏差范围为8.8%~12%。

关 键 词:萃取分离-石墨炉原子吸收光谱法  铁镍基高温合金            掩蔽方法  
文章编号:1000-0593(2006)06-1167-03
收稿时间:2005-03-08
修稿时间:2005-06-18

Determination of As, Pb, Sn, Sb and Bi in High Temperature Iron and Nickel-Based Alloy by Graphite Furnace Atomic Absorption Spectrometry Combined with Liquid-Liquid Extraction
GUO Xing-jia,XU Shu-kun,LI Xiao-zhou,TONG Jian,SUN Ying,GUO Li-li. Determination of As, Pb, Sn, Sb and Bi in High Temperature Iron and Nickel-Based Alloy by Graphite Furnace Atomic Absorption Spectrometry Combined with Liquid-Liquid Extraction[J]. Spectroscopy and Spectral Analysis, 2006, 26(6): 1167-1169
Authors:GUO Xing-jia  XU Shu-kun  LI Xiao-zhou  TONG Jian  SUN Ying  GUO Li-li
Affiliation:1. Chemistry Department of Northeast University, Shenyang 110004, China2. College of Chemistry Science and Engineering, Liaoning University, Shenyang 110036, China3. The Center of Photoelectron and Laser-Biomedical Research, Shenyang Ligong University, Shenyang 110168, China4. Institute of Metals, Chinese Academy of Sciences, Shenyang 110016, China
Abstract:A method was developed for the determination of As, Pb, Sn, Sb and Bi in high temperature iron and nickel-based alloy by graphite furnace atomic absorption spectrometry combined with liquid-liquid extraction. These elements formed complexes with I^- ions and were subsequently extracted into MIBK to be separated from matrix elements. The effects of remnant matrix elements were studied in detail. MeAnwhile, the interferences of other elements, such as W, Nb and Ta, were eliminated with masking method. The recovery rates for As, Pb, Sn, Sb and Bi are in the range of 93%-99 %, and the relative standard deviations are from 8. 8% to 12%.
Keywords:MIBK extraction   GFAAS   High temperature iron and nickel-based alloy   Masking method   As, Pb, Sn, Sb and Bi