首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fluorescence optical fiber sensor for tetracycline
Authors:Wang Y  Liu W H  Wang K M  Shen G L  Yu R Q
Institution:College of Chemistry and Chemical Engineering, Southwest China Normal University, Chongqing 400715, People's Republic of China; College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China.
Abstract:A new optical fiber sensor for monitoring tetracycline has been described, based on the fluorescence quenching of 1,4-bis(5,5'-dimethylbenzoxazole-1',3'-yl-2')benzene incorporated into a thin plasticized polymer film by tetracycline extracted from aqueous phase into film phase. The sensor is fully reversible and highly reproducible. Furthermore, the sensor exhibits a linear response to tetracycline in the range 6.98x10(-7)-8.73x10(-5) mol l(-1) with a detection limit of 1.06x10(-7) mol l(-1), and with the response time <30 s. The response is also selective to tetracycline, with some common pharmaceutical species, alkali and alkali-earth metal salts being highly discriminated, suggesting that the sensor can be used to monitor tetracycline in three pharmaceutical preparations. The recovery of tetracycline from commercial formulations is 95.3-98.3%.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏