首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of nitrogen in steels by alpha-induced prompt gamma-ray spectrometry
Authors:D. Gihwala  I. S. Giles  C. Olivier  M. Peisach
Affiliation:(1) Southern Universities Nuclear Institute, P.O. Box 17, 7131 Faure, (South Africa);(2) Department of Chemistry, University of Stellenbosch, 7600 Stellenbosch, (South Africa)
Abstract:The prompt gamma-ray of 871 keV emitted during the bombardment of steels by 5 MeV alpha particles were used to determine nitrogen by means of the reaction14N(α, pγ)17O. The method is non-destructive, rapid and experimentally simple. It has a sensitivity of about 7 μg·g−1. In the nitrogen concentration range of 101–102 μg·g−1 the relative precision of the method is about 3%. The accuracy of the method compares with that of other nuclear methods. Presented at the 5th Symposium on Recent Developments in Activation Analysis, Oxford, 17–21 July, 1978.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏