首页 | 本学科首页   官方微博 | 高级检索  
     检索      

离子色谱法测定减水剂中硫酸钠含量
引用本文:杨学灵,林瑛.离子色谱法测定减水剂中硫酸钠含量[J].广州化学,2012,37(3):5-9.
作者姓名:杨学灵  林瑛
作者单位:中国科学院广州化学研究所,广东广州,510650
摘    要:建立了离子色谱法测定减水剂中硫酸钠含量的方法。减水剂试样溶于水中,采用201×7(717)强碱性阴离子交换树脂去除溶液中的有机物,进样量为20μL。在Metrosep A SUPP 5-250型阴离子分离柱上,以3.2mmol/L Na2CO3和1.0mmol/L NaHCO3混合溶液作为淋洗液,抑制型电导检测,以0.6mL/min流量洗脱,按峰面积定量。方法检出限(3S/N)为0.05mg/L。用标准加入法,以实体为基体进行回收试验,测得回收率为96.3%~104.3%。

关 键 词:离子色谱法  硫酸钠  阴离子交换树脂

Ion Chromatography Determination of Sodium Sulfate in Water Reducing Agent
YANG Xue-ling,LIN Ying.Ion Chromatography Determination of Sodium Sulfate in Water Reducing Agent[J].Guangzhou Chemistry,2012,37(3):5-9.
Authors:YANG Xue-ling  LIN Ying
Institution:( Guangzhou Institute of Chemistry, Chinese Academy of Sciences, Guangzhou 510650, China)
Abstract:Ion chromatography was applied to the determination of sodium sulfate (as SO42) in water reducing agent. The water reducing agent was dissolved in water. 201×7(707) strongly basic anion exchange resin was used to remove organic substances from the sample solution. An aliquot (20 μL) of the eluate from 201×7(707) strongly basic anion exchange resin was taken for IC determination. The Metrosep A SUPP 5-250 column was used for separation, 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 solutions were used as mobile phase with flow-rate of 0.6 mL/min, and SO42- ion was determined by suppressed conductance detection through measuring values of peak area. Detection limit (3S/D) found was 0.05 mg/L. Values of recovery found by standard addition method were in the range from 96.3%- 104.3%.
Keywords:ion chromatography  sodium sulfate  anion exchange resin