Possibilities and limitations of the total reflection X-ray fluorescence spectrometry for the determination of low Z elements in biological samples |
| |
Authors: | Zsó fia Polgá ri,Norbert Szoboszlai,Mihá ly Ó vá ri,Gyula Zá ray |
| |
Affiliation: | aLorand Eötvös University, Institute of Chemistry, Department of Analytical Chemistry, Laboratory of Environmental Chemistry and Bioanalytics, P.O. Box 32, H-1518, Budapest, Hungary;bCooperative Research Centre of Environmental Chemistry, Eötvös University, Budapest, H-1117, Budapest, Pázmány Péter stny. 1/a., Hungary |
| |
Abstract: | The analytical capability of the laboratory scale vacuum total reflection X-ray fluorescence (TXRF) spectrometer (Wobistrax) was studied for the determination of the Z elements (Na, Mg, P, S, K and Ca) in different biological matrices represented by the following certified reference materials: MURST-ISS-A2 Antarctic krill, IAEA-331 spinach, NIST 1577a bovine liver, and SERONORM™ Trace Elements Serum Level 1.First, the stability of the response factors (relative sensitivity) against Ti internal standard was checked in the concentration range of 1 to 1000 mg/L in a diluted nitric acid matrix. It has been found that the upper limit of the analytical concentration range for K and Ca can be as high as 1000 mg/L; on the other hand, the remaining elements cannot be determined above a concentration of some tens mg/L.The established response factors were used for the elemental analysis of the four certified reference materials after normal-volume microwave assisted acid digestion. In the case of the serum sample, different preparation methods were compared as follow: direct analysis, microwave assisted acid digestion in normal-volume and micro-vessels, as well as the vapor-phase digestion directly on the TXRF carrier plates.On the basis of the results, the normal-volume digestion results in rather high dilution of the samples; thus, elements at low concentration could not be detected in some of the samples. On the other hand, this method offers the highest rate of both organic matrix decomposition and inorganic matrix dilution; thus, the background and the standard deviation of the results were the lowest. In general, this method was found to be useful for the analysis of samples with high dissolved (organic + inorganic) content if the analytes are present at a concentration considerable above the quantification limit.In the case of the microscale and the vapor-phase digestion, both the organic and inorganic matters remain at elevated concentration; thus, higher background and self-absorption of the fluorescent radiation occurred, deteriorating the analytical performance. |
| |
Keywords: | TXRF Low Z elements Microwave assisted digestion Direct analysis Certified reference materials |
本文献已被 ScienceDirect 等数据库收录! |
|