首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An experimental study on the compatibility of acetone with aluminum flat-plate heat pipes
Authors:Jui-Ching Hsieh  David T W Lin  Hsin-Jung Huang  Tzu-Wei Yang
Institution:1. Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu, Taiwan, ROC
2. Institute of Mechatronic System Engineering, National University of Tainan, Tainan, Taiwan, ROC
3. Department of Systems and Naval Mechatronic Engineering, National Cheng Kung University, Tainan, Taiwan, ROC
Abstract:This study investigates the compatibility of aluminum flat-plate heat pipes (FPHPs) used for filling acetone as a working fluid after long-term operation of and the non-condensable gas (NCG) exhausting process. The rate of NCG generation substantially decreased after conducting the NCG exhausting process, proving the compatibility of acetone with the aluminum FPHPs. However, the thermal resistance was not enhanced because hydroxide bayerite (Al(OH)3) was generated as a product of the reaction.
Keywords:
本文献已被 SpringerLink 等数据库收录!