首页 | 本学科首页   官方微博 | 高级检索  
     


Reply to comments on ‘The investigations on K and L X-ray fluorescence parameters of gold compounds'
Authors:E. Cengiz  V. Ayl?kc?E. T?ra?o?lu  G. Apayd?n
Affiliation:Department of Physics, Faculty of Science, Karadeniz Technical University, 61080 Trabzon, Turkey
Abstract:We reply to comments raised in Kumar and Puri (2011). The comments claim that our results may ;be considered inconsequential because of the detector efficiency at Ge K-edge energy and the procedure of the photo-peak area evolution. However, to obtain detector efficiency in different energies, the variation of the factor I0 as a function of the energy was drawn and the error arising from the detector efficiency added to our results. Moreover, the peak fitting procedure was made by the software program and the values of the reduced χ2 and coefficient of determination show that the fits are quite adequate. Therefore, our results may be considered consequential.
Keywords:Ultra-LEGe detector   Detector efficiency
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号