首页 | 本学科首页   官方微博 | 高级检索  
     


Electrochemical Determination of the Anticancer Herbal Drug Shikonin at a Nanostructured Poly(hydroxymethylated‐3,4‐ethylenedioxythiophene) Modified Electrode
Authors:Liping Wu  Limin Lu  Long Zhang  Jingkun Xu  Kaixin Zhang  Yangping Wen  Xuemin Duan  Fan Yang
Affiliation:1. Jiangxi Key Labrotory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, P.?R. China, Tel: +86‐791‐88537967;2. fax: +86‐791‐83823320;3. College of Science, Jiangxi Agricultural University, Nanchang 330045, P.?R. China
Abstract:A simple and sensitive method is described for the electrochemical determination of shikonin, a widely used anti‐tumoral agent, based on its electrochemical oxidation at a nanostructured poly(hydroxymethylated‐3,4‐ethylenedioxy‐thiophene) (PEDOT‐MeOH) electrode, which was fabricated by a facile electropolymerization method. Compared with bare and poly(3,4‐ethylenedioxythiophene) (PEDOT) electrodes, the PEDOT‐MeOH film exhibited a distinctly higher activity for the electrooxidation of shikonin. The PEDOT‐MeOH electrode showed a wide linear response for shikonin in the concentration range from 1.0 nM to 10.0 µM with detection limit of 0.3 nM. Furthermore, the PEDOT‐MeOH electrode displayed high stability, good reproducibility and high sensitivity for the detection of shikonin.
Keywords:PEDOT‐MeOH  Electropolymerization  Shikonin  Modified electrode  Electrochemical determination