首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Nafion修饰碳纤维微电极在抗坏血酸共存下选择性测定去甲肾上腺素
引用本文:李梅,陈慧,伍雪巍,农燕婷,陈思伶,唐旻奕,程寒.Nafion修饰碳纤维微电极在抗坏血酸共存下选择性测定去甲肾上腺素[J].分析测试学报,2016,35(6):744-747.
作者姓名:李梅  陈慧  伍雪巍  农燕婷  陈思伶  唐旻奕  程寒
作者单位:中南民族大学药学院,湖北武汉,430074
基金项目:国家自然科学基金项目(21205144);中南民族大学学术团队(XTZ15013);中南民族大学民族药学十二五实验教学示范中心资助
摘    要:制备了碳纤维微电极,将洁净的碳纤维微电极浸入Nafion溶液中,采用电沉积的方法制得Nafion修饰碳纤维微电极。采用循环伏安法(CV)、差分脉冲伏安法(DPV)研究了去甲肾上腺素(NE)和抗坏血酸(AA)在电极上的电化学行为。结果表明:在最优条件下制备的Nafion修饰电极能完全屏蔽AA的电化学响应,而对NE仍表现出良好的电化学响应。修饰电极能在1.0 mmol/L AA的共存下选择性地测定NE,采用DPV进行检测,NE的氧化峰电流与其浓度在1.0×10~(-6)~1.0×10~(-4)mol/L范围内呈良好的线性关系,相关系数(r~2)为0.991 2,检出限(S/N=3)为8.6×10~(-7)mol/L。利用该方法测定了模拟样品中NE的含量,平均加标回收率为101.6%。该电极的重现性和稳定性良好,且具有良好的灵敏度和选择性,有望用于复杂生物环境中NE浓度的检测。

关 键 词:Nafion  碳纤维电极  差分脉冲伏安法  循环伏安法  去甲肾上腺素  抗坏血酸

Selective Detection of Norepinephrine at Nafion Modified Carbon Fiber Microelectrode in the Presence of Ascorbic Acid
LI Mei,CHEN Hui,WU Xue-wei,NONG Yan-ting,CHEN Si-ling,TANG Min-yi,CHENG Han.Selective Detection of Norepinephrine at Nafion Modified Carbon Fiber Microelectrode in the Presence of Ascorbic Acid[J].Journal of Instrumental Analysis,2016,35(6):744-747.
Authors:LI Mei  CHEN Hui  WU Xue-wei  NONG Yan-ting  CHEN Si-ling  TANG Min-yi  CHENG Han
Abstract:A carbon fiber microelectrode modified with Nafion was fabricated by electrodeposition method on the basis of previous work.The electrochemical behaviour of norepinephrine(NE) and ascorbic acid(AA) at the prepared microelectrodes before and after modification were investigated using cyclic voltammetry(CV) and differential pulse votammetric(DPV) methods.Under the optimum conditions,the Nafion modified-electrode can completely shield the electrochemical response of AA,however,a sensitive response to NE was obtained on the modified electrode.Based on this,the modified electrode can be used to selectively detect NE without interference from high concentration AA.DPV response of NE showed a good linearity(r2=0.991 2) at the modified microelectrode with its concentration in the range of 1.0×10-6-1.0×10-4 mol/L,with a detection limit(S/N=3) of 8.6×10-7 mol/L.The proposed method was applied in the determination of NE in simulation sample with spiked recovery of 101.6%.The modified electrode exhibited almost the same electrochemical behavior after a month,indicating that the modified electrode is pretty stable and has a good reproducibility.The advantages of excellent sensitivity and selectivity made the modified electrode could be used to monitor NE in complex biological environment.
Keywords:Nafion  carbon fiber electrode  differential pulse voltammetry (DPV)  cyclic voltammetry(CV)  norepinephrine(NE)  ascorbic acid(AA)
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《分析测试学报》浏览原始摘要信息
点击此处可从《分析测试学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏