首页 | 本学科首页   官方微博 | 高级检索  
     

气相色谱法直接进样测定工业废气中的苯乙烯
引用本文:肖学喜,何桂英,舒争. 气相色谱法直接进样测定工业废气中的苯乙烯[J]. 化学分析计量, 2012, 21(5): 65-66
作者姓名:肖学喜  何桂英  舒争
作者单位:宁波北仑环境保护监测站,浙江宁波,315800
摘    要:建立了直接进样测定工业废气中苯乙烯的气相色谱法.工业废气样品通过气体进样阀进入气相色谱仪中进行分离和检测,采用0.25 mL气体进样阀时,方法的检出限为1.4 mg/m3,苯乙烯含量在3.19~51.0 mg/m3时,测定结果的相对标准偏差为2.19%~4.50%(n=5),与行业标准HJ 583-2010,HJ 584-2010相比,该方法操作简便、快速,适合工业废气中苯乙烯的快速测定.

关 键 词:气相色谱法  直接进样  苯乙烯含量  工业废气

Determination of Styrene in Industrial Waste Gas by GC with Direct Injection
Xiao Xuexi , He Guiying , Shu Zheng. Determination of Styrene in Industrial Waste Gas by GC with Direct Injection[J]. Chemical Analysis And Meterage, 2012, 21(5): 65-66
Authors:Xiao Xuexi    He Guiying    Shu Zheng
Affiliation:(Environment Protection Monitoring Station of Beilun,Ningbo 315800,China)
Abstract:A method for the determination of styrene in industrial waste gas by GC with direct injection was recommended.Through the gas sampling valve,the industrial waster gas was put into GC to be separated and detected.As 2.5 mL gas sampling valve was used,the detection limit of the styrene was 1.4 mg/m3.As the content of styrene in industrial waster gas were 3.19–51.0 mg/m3,the standard relative deviation of determination results were 2.19% – 4.50%(n=5).Compared with HJ 583–2010 and HJ 584–2010,this method was more simple,fast and suitable for the rapid determination of styrene in industrial waste gas.
Keywords:GC  direct injection  styrene  industrial waste gas
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号