Determination of Atrazine in Vegetable Samples Using a Dipstick Immunoassay Format
Abstract:

A dipstick assay format for atrazine analysis in vegetable samples is described. The analytical method consists in a fast extraction procedure followed by a test based on the use of Immobilon-P strips as antibody coating support. The atrazine quantification was carried out measuring the dot colour by a spectrophotometer. Thus atrazine could be detected in a concentration range 0.16-475.0 µg Lm 1 with an I50 of 2.04 µg L m1. For direct quantification of vegetable samples, those were extracted by blending 5 g in 10 mL of MeOH for 10 min followed by a vacuum filtration through 0.45 µm nylon filters. To avoid erroneous atrazine results, all samples and standards were run in 50% of MeOH which decreased the assay sensitivity by ten fold ( I50 = 21.09 µg Lm1). Therefore, the proposed methodology was able to perform atrazine analysis under established EU MRL. The samples could be measured directly without any prior concentration or clean-up steps. Recoveries (75-105%) were in agreement with those obtained by a reference method (multiresidue extraction-GC/MS quantification). The feasibility of automated immunoreagent dispenser was also demonstrated.
Keywords:Immunoassay  Dipstick  Atrazine  Vegetables