Volatilityrate by thermogravimetry |
| |
Authors: | Q Kwok R J Seyler |
| |
Affiliation: | (1) Canadian Explosives Research Laboratory, Ottawa, Canada, K1A 0G1, ON;(2) Tredegar Film Products, Terre Haute, USA, 47804, IN |
| |
Abstract: | ASTM Committee E37 on Thermal Measurements published a new test method 'Standard Test Method for Volatility Rate by Thermogravimetry' in June 1999 with the designation E 2008. This approach to assessing volatility utilizes an extension of the pinhole technology previously employed by E37 for vapor pressure determinations using differential scanning calorimetry (ASTM E 1782). After publication of the test method E 2008, an Interlaboratory Study was undertaken to develop a 'Precision and Bias' statement to be assigned with the test method. This paper provides some background data that supports the claim that E 2008 is generally insensitive to experimental conditions other than temperature. The Interlaboratory Study showing the statistical review is also discussed. |
| |
Keywords: | interlaboratory study pin-hole technology thermogravimetry volatility rate |
本文献已被 SpringerLink 等数据库收录! |
|