1. Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran 2. Young Researchers Society, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman, Iran
Abstract:
We have synthesized cadmium(II) ion-imprinted polymers (IIP) and non-imprinted polymers (NIP) using 1-(2-pyridylazo)-2-naphthol as a ligand. The materials were used to prepare a carbon paste electrode for the determination of Cd(II). Polymerization was performed with (a) methacrylic acid as a functional monomer, (b) ethyleneglycol dimethacrylate as the crosslinking monomer, and (c) 2,2′-azobis(isobutyronitrile) as the initiator. Imprinted cadmium ion was removed from the polymeric matrix using nitric acid. The measurements were carried out in an closed circuit after accumulation at ?1.2?V, this followed by electrolysis of the accumulated Cd(II) by voltammetric scanning from ?1.0 to ?0.6?V. The parameters governing the response of the electrode were studied. Under optimized conditions, the response of the electrode is linear in the range from 2.0 to 200?ng?mL?1. The detection limit is 0.31?ng?mL?1. The relative standard deviations are ±3.4 and ±2.1?% for 7 successive determinations of 20.0 and 50.0?ng?mL-1 of Cd(II), respectively. The method was applied to the determination of cadmium (II) in water and food samples.
Figure
a) Preparation of modified carbon paste b) Preparation of Cd(II)-IIP-MCPE c) Differential pulse anodic stripping voltammetry d) Voltammogram